Vlc 1600 Datasheet !free! -

: All programming and setup data are stored in non-volatile flash memory, ensuring operation is stable even after power losses. Environmental & Installation Operating Temp : 0 to 158°F (-17 to 70°C). Humidity : 5 to 95% RH, non-condensing.

is a high-performance, fully programmable designed specifically for high-density input monitoring . Manufactured under Honeywell Building Automation, the

: Connect to the BACnet MS/TP LAN using twisted shielded-pair (TSP) cable. vlc 1600 datasheet

is its 16 universal inputs, which remove the need for fixed-type input hardware modules. Depending on the specific datasheet revision (e.g., standard legacy 10-bit vs. enhanced 16-bit software conversions), these inputs accommodate an extensive array of sensor types: Input Signal Type Technical Requirements / Specifications Supports 3k Ωcap omega (Ibex) or 10k Ωcap omega (Type II) thermistors for precision temperature monitoring. Dry Contact

The "VLC-1600" most frequently refers to a native BACnet monitoring device manufactured by Alerton, which is now a brand under Honeywell International. As a dedicated input monitoring device, its primary function is not to control equipment directly but to act as a powerful data acquisition module for various sensor types, integrating seamlessly into a larger Building Management System (BMS) or HVAC (Heating, Ventilation, and Air Conditioning) network. The standard VLC-1600 has no control outputs; it is purely an input device. : All programming and setup data are stored

A datasheet will include a mechanical outline. For a typical VLC 1600 (TO-56 or butterfly package):

The term VLC 1600 is used here as a representative model for a high-performance optical or laser module. While the exact product may vary by manufacturer, the structure and parameters discussed below reflect industry standards for devices in this class. Depending on the specific datasheet revision (e

For those in the manufacturing sector, a detailed datasheet is a prerequisite for any equipment procurement. The following table consolidates the core machining parameters for the FERMAT VLC 1600 ATC+C.

The sensor utilizes a loose push-rod mechanism. The rod is decoupled from the sensing element internally, ensuring that side-loads on the rod do not transfer to the delicate electronic sensing array.

There is also a related model, the , which is a distinct version of the controller that includes a more advanced ARM processor and supports higher communication speeds.

[ BACnet Central Building Management System / Front-End ] │ BACnet MS/TP RS-485 LAN ┌────────────────────────┴────────────────────────┐ ▼ ▼ [ Unitary Controller ] [ Alerton VLC-1600 ] (Valves / Dampers) (16 Sensor Inputs) │ ┌─────────────┴─────────────┐ ▼ ▼ [ Temp Sensor ] [ Pulse Meter ] Physical Layer